View Configuration Diagrams

  • CellarPro 1800 series cooling units are self-contained and fully-charged. They are designed to be installed through-the-wall or just above the cellar in an air-conditioned space (ie. not a hot attic or other unconditioned space)
  • 1800 series units cannot be front ducted but certain models (XT and XTS) offer rear ducting with the purchase of the rear duct hood or rear duct kit add-on.
  • On the cold side, this unit intakes from the front and exhausts cold air from the bottom (so the front 8 inches of the cooling unit must be inside the cellar.)
  • This unit requires fresh air intake at the rear.
  • If the fresh air intake (on the hot side) will receive air below below 40°F, you will require a compressor heater (see add-on options above).
  • If the fresh air intake (on the hot side) will pull air below 20°F, down to -20°F, you must add both the compressor heater and fan cycling switch (see add-on options above).
  • This unit must always be installed and operated in an upright position.